Note: For TC and RTD inputs the decimal figure must be 0 or 1 only. - As a safety measure, always install a circuit breaker (an IEC 60947, compatible product, 5 A, 100 V or 220 V AC) in an easily accessible, location near the instrument. connected to the low-voltage installation. Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features The shallow depth of the controller helps to save instrument panel space. 6. Power supply:100 to 240 VAC (-15 to +10% of the nominal value); Power consumption: 6.0 VA max. Also, YOKOGAWA Electric Corporation assumes no liability for the custo-, mer's failure to comply with these requirements. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. The ambient temperature is in accordance with the operative, 6. The TC10 communication setting criteria are as follows. switch is a device for turning off the power to the instrument. Please, provide a T type 1A, 250 V fuse externally. The Declaration of Conformity and the manual of the controller can. The polarity of the power supply has no importance; The power supply input is NOT fuse protected. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. IP65 rated as "dust tight" and protected against water projected from a nozzle when the optional panel gasket is mounted (for indoor locations) according to EN 60070-1. Digital indicating controllers (476 pages), Program temperature controller (37 pages), Temperature measurement module (44 pages), Manual will be automatically added to "My Manuals", Temperature Controller YOKOGAWA TC10 Engineering Manual, Temperature Controller YOKOGAWA TC10 Quick Manual, Temperature Controller YOKOGAWA TC User Manual, Temperature Controller YOKOGAWA UT55A User Manual, Temperature Controller YOKOGAWA UP150 User Manual, Temperature Controller YOKOGAWA XS550 User Manual, Temperature Controller YOKOGAWA UT130 Technical Information, Temperature Controller YOKOGAWA UT150 User Manual, Temperature Controller YOKOGAWA UT100 Series User Manual. Line resistance: Automatic compensation up to 20W/wire with maximum error 0.1% of the input span. On the TC10, what does it mean if AL and 1 are lit? 7. Note: Every change of the dP parameter setting will produce. Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. facilities, aviation facilities, and medical equipment. What settings should I use to output PV transmission from ananalog output terminal on TC10? Products and components that are subject to wear due to conditions. Clamp meters can perform analyses in the field on live conductors without interrupting the circuit. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. For SSR, mA and V outputs if the line length is longer than 30 m use a shielded wire. The ambient temperature is in accordance with the operative, 6. The relative humidity is in accordance with the instrument, The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - Digital Input (DI2) connecting a free of. At the rst start up the instrument will use a default parameter set (factory parameter set); this set is a generic one (e.g. This manual is intended for the following personnel: - Engineers responsible for installation, wiring, and maintenance of, - Personnel responsible for normal daily operation of the equip-, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. 0.25 to 2.5 mm2 (AWG22 to AWG14) with connection diagram, tightening torque 0.5 Nm; Dimensions: 48 x 48, depth 73 mm, (1.89 x 1.89 x 2.87 in. It also includes a ladder sequence function. There's no SG terminal for wiring RS485 communication on the TC1. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. fail to observe these instructions when operating the product. We call this set conguration parameter set (or conguration parameters). All information about the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. Compliance: directive EMC 2004/108/CE (EN 61326-1), directive LV 2006/95/CE (EN 61010-1). Are the TC10s wiring terminals screw terminals? Model: TC10 - Quick Guide . IP65 Certification when the optional panel gasket is mounted. (24 VAC/DC), 6.0 VA max. There is minimum vibrations and no impact; There are no water or other uids (i.e. It has been designed AL on the front of the TC10 is the alarm lamp. and workmanship for 18 months from the date of manufacturing. There are no water or other uids (i.e. It has been de- signed with compliance to the European Directives. 3 2.3 OUTPUTS Safety notes: - To avoid electrical shocks, connect power line at last. Product Manual Product Specs Overview Description Documents In Stock user must refer to the Engineering manual for special instructions. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. The shallow depth of the controller helps to save instrument panel space. Search the full list . TC10 does not come with a terminal cover. - Modification of the product is strictly prohibited. Yokogawa Electric Corporation for this Product in the EEA. Yokogawa TC10-L Temperature Controller Datasheet PDF, Yokogawa TC10-L Limit Controller Quick Reference Guide, Yokogawa TC10-L Temperature Controller Manual PDF, Yokogawa TC10-L Temperature Controller Brochure PDF, Yokogawa UT150L to TC10-L Cross Reference Guide PDF, Universal Input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), Includes one digital input for external limit reset. This is a list of recorder and controller products that support the New Legislative Framework (NLF.). Yokogawa TC10-L Manual Download for 1 TCTC10- L LIMIT CONTROL TYPE Engineering Manual Code: IM 05C01E81-12EN First edition: Nov. 2019 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. View online Manual for YOKOGAWA TC 10-L Controller or simply click Download button to examine the YOKOGAWA TC 10-L guidelines offline on your desktop or laptop computer. When a shielded cable is used, it should be connected at, 4. Approximately 2 seconds or less. the controller use can be found in the Engineering Manual: IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O, Upload manuals that we do not have and get. 3. 1. ), Panel cutout: 45[-0, +0.6] x 45[-0, +0.6] mm, (1.78[- 0.000, +0.023] x 1.78[- 0.000, +0.023] in.). Use of the in-, strument in a manner not prescribed herein may compromise the, product's functions and the protection features inherent in the, device. The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Looking for more information on our people, technology and solutions? Yokogawa TC10-L Limit Controller Starting at $329.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Some models in stock. : control, alarms, output functions). When installing the TC10, what is the depth in millimeters from the surface of the panel? "), 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns. Can I use the DI function to switch between auto/manual and between run stop/start? There is no parameter for specifying the output direction. If thePV does not exceed SP, after the conrming operation, output relay will be energized (closed) and the output (OUT) display lamp turns off . user must refer to the Engineering manual for special instructions. SSc allows the scaling of the analog input to set the minimum displayed/measured value. 0/4 to 20 mA input wiring for passive transmitter using the auxiliary pws. condensation); 5. Moreover, provide indication that the. - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. Only wire the other instruments SG terminal. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional), Power consumption: 4.5 VA max. There is no parameter for specifying the output direction. Click here to select options, We're open Mo-Th 8am to 5:30pm. Note: For TC wiring use proper compensating cable preferable shielded. The UT75A also support open networks such as Ethernet communication. - For control relay output, alarm relay output, and power terminal, L H C o R o D o F /GK Temperature Controller, NOTE about the structure of this document, The usual installation sequence is the reverse of the operator, During installation, the first step is the wiring procedure followed, by the complete configuration. The factory default password for conguration parameters is equal to 30. Note: The group selection is cyclic as well as the selection of the parameters in a group. Type: Instructions manual . Can I output in the 100% direction (20 mA or more) upon burnout? I want to use it as a display. the protection provided by this instrument may be impaired. A ladder sequence function is included as standard. Can't find your region? All information about the controller use can be found in the Engineering Manual: - IM 05C01E81-02EN and the Communication Manual: IM 05C01E81-03EN and General Specification: GS 05C01E81-01EN. 2. Notes: 1. TEMPERATURE . The conguration parameters are collected in various groups. SSR outputs are not isolated. With the /GK suffix, the TC10 supports the IP65. It has been designed, with compliance to the European Directives. Fr 8am to 5pm ET, The Yokogawa TC10-L Temperature Controller is recommended replacement. To change these parameters you need to enter the Conguration mode. Such, applications include nuclear power equipment, devices using, radioactivity, railway facilities, aviation equipment, air navigation. TC10 is a panel mounting, Class II instrument. If so used, it is the user's responsibility to include in the system additional. The short depth of the controller helps save instrument panel space. The 3-year warranty extends 36 months after shipment from our factory. and workmanship for 18 months from the date of manufacturing. Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. (100 to 240 VAC); Insulation voltage: 2300 V rms according to EN 61010-1; Total Accuracy: 0.5% F.S.V. - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. TC10-L is a panel mounting, Class II instrument. On burnout, it will be 0 mA. . [3] SSc - Initial scale read-out for linear inputs. Do not use it, for measurements in locations falling under Measurement Catego-, For measurements performed on circuits not directly, For measurements performed on circuits directly. terminal 1 and 2 to transmitter signal output. Do not short-circuit the terminals of the SSR output. The UT32A-D is a compact digital indicating controller with selectable 2-loop control. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. Search the full list . The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. For different configurations, see, Wattmeter (instantaneous power expressed in kW) (note 1), Wattmeter (Power consuption expressed in kWh/h) (note 2), Absolute worked time (expressed in days) (note 3), Absolute worked time (expressed in hours) (note 3), Notes: 1. 3. Cold junction accuracy: 0.04C/C after a warm-up of 20 minutes. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. The UT55A/UT52A also support open networks such as Ethernet communication. Copyright 1994-2023 Yokogawa Electric Corporation, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type), Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), IP65 front panel (when the optional panel gasket is mounted)(optional). Does the TC10 come with a terminal cover? Every change of the SEnS parameter will produces a change of the related parameter and in particular: [11] Ao1L and [12] Ao1H (when the analog retransmission is present) will be forced to the Ex.Range limits. All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN. WARNING! - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. I want to use it as a display. 1. External components (like zener barriers, etc.) 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. What is the measured current of the TC10's RTD input? Brand: digitalview. Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. Relay output 2,3: 2A, 250 V AC, resistive load. I selected SP value transmission on TC10, but no SP value is displayed. 2.2.2TD Pt 100 Input 1R - For control relay output, alarm relay output, and power terminal. Backed by the high reliability and quality that Yokogawa has cultivated over many years. If the password is correct the display will show the acronym of the rst parameter group preceded by the symbol: ]. Input impedance:> 1 M. The 3-year warranty extends 36 months after shipment from our factory. When using an external power supply with 2-wire wiring of TC10, what is the input resistance when inputting 4-20 mA? Looking for more information on our people, technology and solutions? The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. The UT75A also support open networks such as Ethernet communication. It has been designed, with compliance to the European Directives. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. The UT55A/UT52A also support open networks such as Ethernet communication. codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions. There are no water or other fluids (i.e. Notes: 1. requirements of the area in which the instrument is being installed. The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery. voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. The TC10 supports easy configuration with codes for quick start-up. TC10s compact design allows for a broad range of applications/uses while maintaining a high level of accuracy. Select a mounting location having the following characteristics: 2. condensation); 5. The UT52A/MDL supports 920 MHz band wireless communication. 2. 2.The cable length must not exceed 1.5 km at 9600 baud. - Modification of the product is strictly prohibited. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. , we recommend to congure the parameters to. Controller YOKOGAWA TC 10-L Engineering Manual, Controller YOKOGAWA UT350 Instruction Manual, Controller YOKOGAWA FX103 User Manual, Controller YOKOGAWA UT32A User Manual, Controller YOKOGAWA UTAdvanced UT35A Technical Information. codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions. Can't find your region? A ladder sequence function is included as standard. A reinforced isolation must be assured by the external solid state relays. This manual describes how to use UT55A/UT52A functions other than UT55A/UT52A's communication function and ladder sequence function . Notes: 1. The TC10-N can be easily configured by the "Code Configuration" method for the most common requirements, just entering two 4-digit. Controller YOKOGAWA TC 10-L Engineering Manual 20 pages. I'm sending the temperature via PV transmission on TC10. There is minimum vibrations and no impact; 4. I selected SP value transmission on TC10, but no SP value is displayed. All information about. requirements of the area in which the instrument is being installed. Model: TC10 Digital Indicating Controller with one universal input, one control output, and one selectable I/O. Safety, Protection and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. I want to use the detailed parameter setting method of TC10, but what number is the password? Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display Universal input: (TC, mV, V, mA, Pt100-Pt1000) 4 Set Points and alarm functions Serial communication : RS-485 Modbus PID control, ON/OFF, Auto-tuning D + D - D + D - D + D - D + D - RS-485 5 6 connected, between sensor and input terminals may cause errors in, measurement due to excessive and/or not balanced line, 3. It has been de- signed with compliance to the European Directives. Id like to confirm the parameters that can be set for TC10 RS485 communication setting criteria (protocol, baud rate, parity, stop bit, data length). Use a tester or similar device to ensure. External components (like zener barriers, etc.) It has been designed with compliance to the European Directives. CONTROLLER Engineering Manual. At this point the instrument restarts as for a new power ON. [4]FSc - Full scale read-out for linear input. The shallow depth of the controller helps save to space. IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument.
Natural Water Slides San Isabel Directions,
Jose Torres El Rey De Alto Mando Biografia,
Cuanto Cobra Grupo Firme Por Evento,
Articles Y